The scholar and what he brought to us
Aiman (a pseudonym), a second-year PhD candidate in electrical engineering at a Malaysian public university, booked a mentoring session with the PhD Research Lab on 4 August 2026, about six weeks before his planned fieldwork. His study looked at how soiling and humidity reduce the output of photovoltaic (PV) systems on the east coast of Peninsular Malaysia, and how operations and maintenance (O&M) teams decide when to clean panels.
His question was narrow: “Can you check that my questionnaire is ready to send?” We looked at the whole data plan instead, because problems in an engineering PhD usually start one or two stages before the point where they surface.
What our diagnostic review found
| Stage | What we found | Why it mattered |
|---|---|---|
| Proposal | Generation and cleaning-log data were promised by a solar operator in an informal conversation with a site manager. | Both main research questions depended on this data, and there was no fallback. |
| Approvals | The scholar assumed an engineering study did not need ethics review and planned to pilot the questionnaire with colleagues first. | At the University of Malaya, for example, no participant may be approached, even for a pilot, before approval (UMREC-NM, n.d.). |
| Pilot | Sensors were calibrated only in the laboratory, with no plan to log humidity, rainfall or cleaning events. | East-coast sites are hot, very humid and wet-dusty; soiling losses there are large and variable (Islam et al., 2022). |
| Main collection | An English-only questionnaire would go out through one professional body’s mailing list. | It would reach mostly senior Professional Engineers and miss the graduate engineers who do most O&M work. |
| Data management | Raw logger files were renamed and overwritten in one shared folder. | Examiners could not trace figures back to raw data or judge measurement error. |
Securing the data before anything else
We drafted a one-page data access request listing the exact variables (inverter output, irradiance, module temperature, cleaning dates), period, resolution, format, how site names would be anonymised and what the operator could review before publication. The supervisor sent it on university letterhead, because operators route such requests through legal and compliance teams rather than site staff.
We also agreed a fallback that could answer a narrower version of the question: the scholar’s own test rig plus published Malaysian soiling studies. One 12-month study of a 2.5 MW PV site in Terengganu reported an average soiling loss of 26.22%, ranging from 4.86% to 58.67% (Jamil et al., 2020, as reported by Islam et al., 2022).
Ethics approval and personal data
The O&M survey and interviews were research with human participants. Ethics review in Malaysia runs mainly through university committees, guided by the Malaysian Code of Responsible Conduct in Research (National Science Council, 2020), so the scholar checked his own university’s rules and moved the pilot to after approval.
The operator’s cleaning logs contained technicians’ names. The Personal Data Protection Act 2010 governs personal data processed in commercial transactions, so the operator was bound by it (Lex Mundi, n.d.), and the 2024 amendments, in force in phases during 2025, added data protection officers, breach notification and data portability (ASEAN Briefing, 2025). We advised asking the operator to remove names before release. Because one co-supervisor was overseas, we also flagged the 2025 cross-border transfer guidelines and asked the scholar to agree where the data would be stored (Mayer Brown, 2025).
A pilot for humid, wet-dust conditions
The site’s relative humidity is around 80–90% in the rainy season and the dust that settles on panels tends to be wet (Islam et al., 2022); haze episodes have also affected solar generation in the region (Maghami et al., 2015). The new pilot ran for two weeks on site into the start of the monsoon period, with calibration checks before and after, ambient temperature, humidity and rainfall logged alongside the PV variables, a manual log of every cleaning event, and an end-of-pilot check of enclosure seals for condensation.
Reaching the engineers who do the work
As of 31 July 2025, the Board of Engineers Malaysia register held 219,268 Graduate Engineers but only 18,130 Professional Engineers (Wan Harun, 2025). A sample drawn from senior contacts would describe a small, unrepresentative group. We set a target sample size in advance, added a back-translated Bahasa Malaysia version, recruited through O&M contractors, project sites, the Institution of Engineers Malaysia and alumni networks, and tracked responses weekly by registration grade and region.
Making every figure traceable
We set up a read-only raw folder, a processed folder, a decision log for every cleaning or exclusion step and version-controlled scripts, aligned with the FAIR principles (Wilkinson et al., 2016), and drafted a measurement uncertainty budget for each sensor following the GUM (JCGM, 2008).
What changed
| Area | Before | After |
|---|---|---|
| Partner data | Verbal promise from a site manager | Written request with variables, period and anonymisation; fallback agreed |
| Ethics and PDPA | No ethics application; pilot with colleagues | Ethics application before any contact; names removed by operator; storage agreed |
| Pilot | Laboratory calibration only | On-site wet-season pilot with drift, weather and cleaning events logged |
| Sample | English-only, one mailing list | Bahasa Malaysia and English; four channels; weekly tracking |
| Records | Overwritten files | Raw and processed split, decision log, version control, uncertainty budget |
For the full stage-by-stage guide behind these steps, read Engineering PhD Data Collection in Malaysia.
What this case taught us
- The question scholars bring is rarely the real problem. This one was about a questionnaire; the bigger risk was a dataset that did not yet exist on paper.
- Engineering studies involve people more often than expected. Surveys, interviews and logs with names bring in ethics review and data protection.
- A laboratory calibration is not a field calibration. In humid, wet-dust conditions the pilot must include the weather the campaign will face.
- Who you can reach decides what you can claim. A sample built from senior contacts over-represents Professional Engineers.