Why collection decides the quality of the thesis
Clinical and epidemiological PhDs draw on two broad kinds of data. Primary data are collected for the study itself, through questionnaires, interviews, clinical measurements, biological samples or trial procedures. Secondary data, such as electronic health records (EHRs), registries and administrative databases, were collected for other purposes and are reused. Many doctoral projects combine the two, for example a cohort that links study questionnaires to hospital records.
Either way, the quality of the data sets a ceiling on the quality of the findings. A precise model fitted to misclassified exposures or inconsistently measured outcomes gives a precise but wrong answer. A questionnaire study that also measures cortisol, for instance, is a strong multi-method quantitative design, but only if sampling times, assay methods and storage are standardised; it becomes mixed methods only if qualitative data are collected and integrated. The rest of this guide sets out how to protect quality at each stage.
Ethics, good clinical practice and data protection
The Declaration of Helsinki, revised by the World Medical Association in October 2024, remains the core ethical framework for medical research involving human participants (World Medical Association, 2025). It requires review by an independent research ethics committee before the study begins, free and informed consent, protection of privacy and confidentiality, particular care for participants in vulnerable situations, and registration of research in a publicly accessible database before recruitment. The 2024 revision consistently refers to "participants" rather than "subjects".
If your project is a clinical trial, it must also follow good clinical practice. The International Council for Harmonisation adopted the third revision of its guideline, ICH E6(R3), in January 2025 (International Council for Harmonisation, 2025). It is written as principles rather than a fixed checklist and asks sponsors and investigators to build quality into the design, focus effort on the factors critical to the reliability of results and participant safety, and apply controls proportionate to risk, including for data governance and computerised systems. Check which parts your university, as sponsor, expects a doctoral trial to apply.
Data protection law is a separate obligation. In the European Union and the United Kingdom, the General Data Protection Regulation (in its EU and UK versions) governs personal data, and health data receive extra protection; elsewhere, laws such as HIPAA in the United States apply. Consent to take part in research is not necessarily the legal basis for processing the data, so agree the basis, retention period and pseudonymisation plan with your data protection officer. Where interviews form part of the project, the same principles of voluntary participation, anonymity, privacy and confidentiality apply to recordings and transcripts (Nii Laryeafio & Ogbewe, 2023).
Plan collection from the protocol
Write the protocol before you design any form. SPIRIT 2025 sets out what a trial protocol should contain, including the outcomes, their timing, the sample size and the plans for data collection and management (Chan et al., 2025), and its structure is useful for observational studies too. If patient-reported outcomes are central, the SPIRIT-PRO extension lists additional protocol items (Calvert et al., 2018).
Then work backwards from analysis. For each objective, list the outcome, exposures or interventions, confounders and effect modifiers, and the time points at which each is measured. A statistical analysis plan written early (Gamble et al., 2017) exposes items you would otherwise forget to collect, and items you are collecting for no reason. Record the result in a data dictionary: one row per variable, with its name, definition, type, units, permitted values and source.
Design case report forms that prevent errors
A case report form (CRF), paper or electronic, is the instrument that turns observations into data. Good forms share a few features.
- One question, one variable. Avoid compound questions and free text where a coded answer will do.
- Units and formats fixed. State units on the form (mmol/L, not "glucose") and use date pickers or fixed formats.
- Explicit missing codes. Distinguish "not done", "not applicable" and "unknown" so that missing data can be described and handled properly at analysis.
- Standard definitions. Use validated instruments and established definitions, and consider data standards such as CDISC's CDASH for common clinical fields, which make data easier to combine and share.
- Piloted. Test the form with a small number of participants and the staff who will use it, then revise it before the study opens.
Electronic data capture and EHR data
Electronic data capture (EDC) systems apply validation at the moment of entry. REDCap, developed at Vanderbilt University and widely available to universities through its consortium, builds forms from a data dictionary (its metadata-driven design) and supports range checks, branching logic, user roles and an audit trail of every change (Harris et al., 2009). Using the same data dictionary for the form, the codebook and the analysis keeps them aligned.
Transferring data directly from EHRs into EDC systems can reduce transcription, but it is not yet straightforward. In a German feasibility study, Mueller et al. (2023) found that 67 of the 274 variables in the study forms (24%) could be transferred automatically from practice management systems, and showed that secure, GDPR-compliant end-to-end transfer was feasible. The remaining variables still needed manual entry, which is typical: expect EHR extraction to supplement rather than replace a CRF.
When you reuse EHR or registry data, assess their quality explicitly. Kahn et al. (2016) propose a harmonised framework with three categories: conformance (do values follow the expected format and coding), completeness (are values present when they should be) and plausibility (are values believable). Weiskopf and Weng (2013) reviewed methods for assessing EHR data quality across dimensions including completeness, correctness and currency. Report the code lists and algorithms used to define exposures and outcomes, and the validation of those definitions, as the RECORD extension of STROBE requires (Benchimol et al., 2015; von Elm et al., 2007).
Measurement, recruitment and monitoring
Standardise measurements and samples
Clinical measurements vary with the device, the observer and the circumstances, so write a standard operating procedure for each one. For blood pressure, that means the device model and calibration, cuff size, rest period, posture and which readings are averaged. For biological samples, specify the time of collection (essential for markers with a daily rhythm, such as cortisol), the processing delay, storage temperature and labelling, and keep a chain-of-custody log linking each sample to a pseudonymised identifier. Where outcomes involve judgement, such as reading an image or classifying a cause of death, keep the assessor unaware of exposure or allocation where possible.
Keep recruitment and screening logs
Record everyone who was screened, found eligible, invited, consented, excluded or lost, with reasons. These logs feed the participant flow diagram that readers expect, and STROBE asks observational studies to report the numbers of individuals at each stage of the study and the reasons for non-participation (von Elm et al., 2007). They also show early whether the people you are recruiting differ from the population you intend to describe.
Monitor as you go
Quality control works best as a routine, not a rescue. Train everyone who collects data with a written manual and practice cases, and check agreement between data collectors early. Run reports of missing fields, out-of-range values and overdue visits weekly, raise queries with sites while records are fresh, and log every correction. Track recruitment and retention against the plan, because falling behind is far easier to correct in month three than in month eighteen.
Document as you go. Keep the data dictionary, form versions, standard operating procedures and a decision log under version control, and store raw data separately from cleaned data. Rich metadata make the dataset findable, accessible, interoperable and reusable under the FAIR principles (Wilkinson et al., 2016), which many funders and journals now expect, and make your thesis methods chapter much easier to write.
| Report | Why examiners and reviewers need it |
|---|---|
| Ethics approval, registration and consent procedure | Shows the study met the Declaration of Helsinki and local requirements |
| Setting, dates and recruitment route | Lets readers judge to whom the results apply |
| Measurement procedures, instruments and devices | Allows replication and judgement of measurement error |
| Data capture system, validation and monitoring | Shows how errors were prevented and detected |
| Code lists and algorithms for EHR-derived variables | Required by RECORD; lets others reproduce definitions |
| Participant flow and missing data by variable | Required by STROBE; shows possible selection and information bias |
A worked example
The extract below is hypothetical and purely illustrative. A doctoral cohort study of blood pressure control in primary care defines its key variables before any data are collected.
| Variable | Definition and units | Permitted values | Validation rule | Source |
|---|---|---|---|---|
| sbp_v1 | Systolic BP at visit 1, mean of 2nd and 3rd readings (mmHg) | 70 to 250 | Hard stop outside range; warning above 200 | CRF, calibrated device |
| bp_device | Device model used | Coded list | Required if sbp_v1 entered | CRF |
| diabetes | Recorded diagnosis before baseline | 0 = no, 1 = yes, 9 = unknown | Required | EHR code list (version-controlled) |
| hba1c | Most recent HbA1c within 12 months (mmol/mol) | 20 to 200 | Warning if outside range; date required | EHR extraction |
| consent_link | Consent to link study data with health records | 0 = no, 1 = yes | Blocks EHR fields if 0 | Consent form |
Each row ties a variable to a definition, a check and a source. The consent field shows how ethical requirements can be built into the system itself, so that linked data are never collected for a participant who declined linkage.
Common mistakes
- Designing forms before the protocol and analysis plan are settled.
- Collecting variables with no planned use, which adds burden and missing data.
- Leaving units, formats or missing-data codes undefined.
- Treating ethics approval as covering data protection, or vice versa.
- Assuming EHR data are complete and accurate without checking conformance, completeness and plausibility.
- Changing forms mid-study without version control or a record of the change.
- Waiting until the end of collection to look at data quality.
A good final check is to ask whether someone outside your team could take your protocol, data dictionary and forms and collect comparable data in another hospital. If they could not, the collection is not yet specified well enough.
Key takeaways
- Follow the 2024 Declaration of Helsinki, and ICH E6(R3) good clinical practice if your study is a trial (World Medical Association, 2025; International Council for Harmonisation, 2025).
- Plan collection from a SPIRIT-style protocol and an early analysis plan, recorded in a data dictionary (Chan et al., 2025; Gamble et al., 2017).
- Build validation, missing-data codes and audit trails into case report forms and EDC systems such as REDCap (Harris et al., 2009).
- Check EHR data for conformance, completeness and plausibility before reuse, and report definitions using RECORD (Kahn et al., 2016; Benchimol et al., 2015).
- Monitor quality throughout collection and document data so that they are FAIR (Wilkinson et al., 2016).